Hydrogen Gas Durability Evaluation Testing Machine HPH2CTS-90

Features

The cyclic fatigue test can be performed in the temperature range of -40 °C to +85 °C depending on the environmental tank.

●This equipment is possible to perform the cyclic fatigue test with hydrogen gas at a maximum pressure of 140 MPa and a discharge amount of 6 Nm3/h under the temperature condition of -40 °C to +85 °C.
●The valve can be opened and closed remotely by operation control panel, and testing can be performed safely and by automatic control.
●The operator control panel can set the pressure and temperature monitoring, data acquisition and test conditions.
●In the event of hydrogen gas leakage or other problems, the interlock function stops the supply of power and gas and release the gas in the piping to the atmosphere.
Main Specifications
Operating pressure range0.15 MPa to 140 MPa
Operating temperture-40 °C to +85 °C
ConfigurationsEnvironmental vessel for specimen
High and low pressure hydrogen gas compressor
Ultra-low pressure hydrogen gas compressor
High and low pressure accumulator
Recovery tank
Operation control panel
Temperature control unit, etc.
Environmental vessel for specimen
Max. pressure0.7 MPa
Temperture range-40 °C to +85 °C
Accumulator
PressureHigh-pressure accumulator: Max. : 140 MPa
Low-pressure accumulator: Max. : 99 MPa
TemperatureHigh-pressure accumulator: Max. : +40 °C
Low-pressure accumulator: Max. : +40 °C